Designing Masonry Walls for Metal Buildings Warren MI

If the top and bottom of the wall are continuously supported, then the masonry wall will span 12 feet vertically.If you cannot use the roof structure to support the top edge of the wall, install a very stiff steel beam or a beam combined with horizontal reinforcement in the top several feet of the wall.

A Ct
(586) 772-1660
25530 SchoenheRR Rd
Warren, MI
 
Debacker & Sons
(586) 775-8700
21750 Schmeman Ave
Warren, MI
 
Silverado Construction Inc
(586) 758-2600
2055 E 9 Mile Rd
Warren, MI
 
K C Masonry And Concrete Impressions
(586) 795-9401
6345 Product Dr
Sterling Heights, MI
 
Unique Pools & Masonry
(586) 610-9939
33567 Ryan Rd
Sterling Heights, MI
 
Builder Mike
(586) 446-4640
11193 E 13 Mile Rd
Warren, MI
 
Expert Construction Co
(586) 293-0920
31056 Shawn Dr
Warren, MI
 
Marcel Construction
(586) 757-8392
26242 Grobbel Ave
Warren, MI
 
Giannola Masonry Co
(586) 792-2070
35086 Cordelia St
Clinton Township, MI
 
All Pro Masonry
(586) 868-3860
4778 Dunkirk Ct
Sterling Heights, MI
 

Designing Masonry Walls for Metal Buildings

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 1991

One of our current projects is a pre-engineered metal building with a 12-foot eave height. The rigid frames are 30 feet on center. The exterior walls are 8-inch concrete masonry, to be supported at the top with a structural steel member spanning 30 feet between frames. Horizontal deflection of the top wall support and the rigid frame must be considered together. What are your minimum deflection recommendations? Can the concrete masonry tolerate greater than L/600 deflections?
A simple, efficient way to control deflection along the top edge of the wall is to design and detail the roof structure to act as a diaphragm, rather than to design a beam spanning 30 feet. If the top and bottom of the wall are continuously supported, then the masonry wall will span 12 feet vertically.If you cannot use the roof structure to support the top edge of the wall, install a very stiff steel beam or a beam combined with horizontal reinforcement in the top several feet of the wall. In either case, don't use rule-of-thumb deflection limitations to design the beam. Instead, design the steel beam stiff enough to prevent stresses in the wall from exceeding levels allowed by code. The percentage of loads handled by the masonry should be based on relative stiffness. The size of the steel beam may be reduced greatly by using reinforced masonry in conjunction with the beam.

Click here to read full article from Masonry Construction