Brick Veneer Bowing Traverse City MI

This is fairly common in masonry veneer high-rise buildings in Traverse City where relieving angles are used without horizontal expansion joints. During construction, a small gap generally is left between the bottom of each relieving angle and the top of the brick below.

Tip-Top Chimney Sweep
(810) 234-5000
3714 W Court St
Flint, MI
 
Rose Tile & Masonry
(734) 662-8004
1917 Dunmore Rd
Ann Arbor, MI
 
Bornor Restoration Inc
(517) 482-1625
525 Filley St
Lansing, MI
 
Debacker & Sons
(586) 775-8700
21750 Schmeman Ave
Warren, MI
 
R J Masonry
(517) 455-0099
1535 Linval St
Lansing, MI
 
Marcel Construction
(586) 757-8392
26242 Grobbel Ave
Warren, MI
 
Tozier'S Chimney Sweeping
(517) 372-7805
6141 Beechfield Dr Apt 203
Lansing, MI
 
Omega Construction & General Repair
(734) 665-8154
4042 Ann Arbor Saline Rd
Ann Arbor, MI
 
A & A Construction
(517) 367-0000
1039 1/2 S Pennsylvania Ave
Lansing, MI
 
Kennedy Masonry Inc
(517) 322-9310
6554 Sloan Hwy
Lansing, MI
 

Brick Veneer Bowing

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: July 1, 1993

On a 20-story brick-veneer building, the masonry is bulging and cracking at each relieving angle. The building has no horizontal expansion joints. Could the cracking result from brick expansion? What can be done?

This is fairly common in masonry veneer high-rise buildings where relieving angles are used without horizontal expansion joints. During construction, a small gap generally is left between the bottom of each relieving angle and the top of the brick below. As the masonry grows due to moisture and thermal expansion, the gap between the masonry and the shelf angle narrows. Mortar placed at the tip of the angle creates a solid bridge between the masonry above and below the relieving angle. This portion of the joint cannot compress. Resulting forces often cause bowing and spalling. Also look at tie placement. If the nearest ties are more than 12 inches above and below the relieving angle, bowing is more likely. Corrosion of the shelf angle also can cause bowing. Steelcorrosion products are larger than steel itself. This creates pressures that act on the wall similarly to moisture and thermal expansion. These problems are compounded if the building's frame shrinks over time as the masonry expands. Bowing and spalling can be prevented by leaving adequate space beneath each angle during construction. The size of these spaces depends on expected movement. Procedures for sizing joints are given in BIA Tec...

Click here to read full article from Masonry Construction