Brick Veneer Bowing Kalamazoo MI

This is fairly common in masonry veneer high-rise buildings in Kalamazoo where relieving angles are used without horizontal expansion joints. During construction, a small gap generally is left between the bottom of each relieving angle and the top of the brick below.

Builder Mike
(586) 446-4640
11193 E 13 Mile Rd
Warren, MI
 
All Pro Masonry
(586) 868-3860
4778 Dunkirk Ct
Sterling Heights, MI
 
Master Chimney
(810) 424-4002
601 S Saginaw St
Flint, MI
 
Hane Tile & Plastering Mason
(734) 971-8298
2771 Lookout Cir
Ann Arbor, MI
 
Expert Construction Co
(586) 293-0920
31056 Shawn Dr
Warren, MI
 
Dunritebrick
(586) 738-7498
42356 Parkside Cir
Sterling Heights, MI
 
Milhiem Masonry
(616) 485-3740
1102 4th St Nw
Grand Rapids, MI
 
Omega Construction & General Repair
(734) 665-8154
4042 Ann Arbor Saline Rd
Ann Arbor, MI
 
Bashore Marco Masonry Inc
(517) 393-9704
6237 Aurelius Rd
Lansing, MI
 
Draper Group
(616) 304-9332
124 Fulton St E
Grand Rapids, MI
 

Brick Veneer Bowing

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: July 1, 1993

On a 20-story brick-veneer building, the masonry is bulging and cracking at each relieving angle. The building has no horizontal expansion joints. Could the cracking result from brick expansion? What can be done?

This is fairly common in masonry veneer high-rise buildings where relieving angles are used without horizontal expansion joints. During construction, a small gap generally is left between the bottom of each relieving angle and the top of the brick below. As the masonry grows due to moisture and thermal expansion, the gap between the masonry and the shelf angle narrows. Mortar placed at the tip of the angle creates a solid bridge between the masonry above and below the relieving angle. This portion of the joint cannot compress. Resulting forces often cause bowing and spalling. Also look at tie placement. If the nearest ties are more than 12 inches above and below the relieving angle, bowing is more likely. Corrosion of the shelf angle also can cause bowing. Steelcorrosion products are larger than steel itself. This creates pressures that act on the wall similarly to moisture and thermal expansion. These problems are compounded if the building's frame shrinks over time as the masonry expands. Bowing and spalling can be prevented by leaving adequate space beneath each angle during construction. The size of these spaces depends on expected movement. Procedures for sizing joints are given in BIA Tec...

Click here to read full article from Masonry Construction