Brick Veneer Bowing Holland MI

This is fairly common in masonry veneer high-rise buildings in Holland where relieving angles are used without horizontal expansion joints. During construction, a small gap generally is left between the bottom of each relieving angle and the top of the brick below.

Quadratic Masonry Llc
(734) 663-9646
3877 Albert Dr
Ann Arbor, MI
 
Northeast Solite Corp
(810) 232-3088
1071 E Grand Blvd
Flint, MI
 
Milhiem Masonry
(616) 485-3740
1102 4th St Nw
Grand Rapids, MI
 
Grammatico Masonry
(734) 769-4101
435 Evergreen Dr
Ann Arbor, MI
 
A -1 Discount Chimney Sweeps
(616) 241-4336
3261 Division Ave S
Grand Rapids, MI
 
Sivosky Steve
(810) 732-4490
6131 Mapleridge Dr
Flint, MI
 
Stone Doctor
(248) 698-3161
White Lake Twp
Sterling Heights, MI
 
All Pro Masonry
(586) 868-3860
4778 Dunkirk Ct
Sterling Heights, MI
 
Walt'S Construction Co
(810) 787-6852
3906 Milbourne Ave
Flint, MI
 
Tip-Top Chimney Sweep
(810) 234-5000
3714 W Court St
Flint, MI
 

Brick Veneer Bowing

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: July 1, 1993

On a 20-story brick-veneer building, the masonry is bulging and cracking at each relieving angle. The building has no horizontal expansion joints. Could the cracking result from brick expansion? What can be done?

This is fairly common in masonry veneer high-rise buildings where relieving angles are used without horizontal expansion joints. During construction, a small gap generally is left between the bottom of each relieving angle and the top of the brick below. As the masonry grows due to moisture and thermal expansion, the gap between the masonry and the shelf angle narrows. Mortar placed at the tip of the angle creates a solid bridge between the masonry above and below the relieving angle. This portion of the joint cannot compress. Resulting forces often cause bowing and spalling. Also look at tie placement. If the nearest ties are more than 12 inches above and below the relieving angle, bowing is more likely. Corrosion of the shelf angle also can cause bowing. Steelcorrosion products are larger than steel itself. This creates pressures that act on the wall similarly to moisture and thermal expansion. These problems are compounded if the building's frame shrinks over time as the masonry expands. Bowing and spalling can be prevented by leaving adequate space beneath each angle during construction. The size of these spaces depends on expected movement. Procedures for sizing joints are given in BIA Tec...

Click here to read full article from Masonry Construction