Brick Veneer Bowing Grand Rapids MI

This is fairly common in masonry veneer high-rise buildings in Grand Rapids where relieving angles are used without horizontal expansion joints. During construction, a small gap generally is left between the bottom of each relieving angle and the top of the brick below.

Draper Group
(616) 304-9332
124 Fulton St E
Grand Rapids, MI
 
Stillson Masonry
(616) 454-7540
1227 Houseman Ave Ne
Grand Rapids, MI
 
A -1 Discount Chimney Sweeps
(616) 241-4336
3261 Division Ave S
Grand Rapids, MI
 
City Basement
(616) 249-0899
1260 44th St Se
Grand Rapids, MI
 
Taylor Concrete and Masonry
(313) 412-3997
359 beech
westland, MI
Services
Concrete driveway,sidewalks,brick repair
Hours
7 days a week
Membership Organizations
Angies list

Westerhof Masonry Llc
(616) 364-6424
2427 Valentine Blvd Ne
Grand Rapids, MI
 
Van Houten Masonry Inc
(616) 364-4140
3755 4 Mile Rd Ne
Grand Rapids, MI
 
Masonry Aesthetics Group
(616) 742-9970
1350 Scribner Ave Nw
Grand Rapids, MI
 
Milhiem Masonry
(616) 485-3740
1102 4th St Nw
Grand Rapids, MI
 
Milhiem Masonry
(616) 485-3740
1102 4th St Nw
Grand Rapids, MI
 

Brick Veneer Bowing

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: July 1, 1993

On a 20-story brick-veneer building, the masonry is bulging and cracking at each relieving angle. The building has no horizontal expansion joints. Could the cracking result from brick expansion? What can be done?

This is fairly common in masonry veneer high-rise buildings where relieving angles are used without horizontal expansion joints. During construction, a small gap generally is left between the bottom of each relieving angle and the top of the brick below. As the masonry grows due to moisture and thermal expansion, the gap between the masonry and the shelf angle narrows. Mortar placed at the tip of the angle creates a solid bridge between the masonry above and below the relieving angle. This portion of the joint cannot compress. Resulting forces often cause bowing and spalling. Also look at tie placement. If the nearest ties are more than 12 inches above and below the relieving angle, bowing is more likely. Corrosion of the shelf angle also can cause bowing. Steelcorrosion products are larger than steel itself. This creates pressures that act on the wall similarly to moisture and thermal expansion. These problems are compounded if the building's frame shrinks over time as the masonry expands. Bowing and spalling can be prevented by leaving adequate space beneath each angle during construction. The size of these spaces depends on expected movement. Procedures for sizing joints are given in BIA Tec...

Click here to read full article from Masonry Construction