Anchoring Columns to CMU Wythes Holland MI

When masonry walls in Holland are constructed independent of the steel structure, anchorage of the masonry to the steel column is not required if the walls span vertically and are supported laterally by floors and roofs acting as diaphragms or structural members.

Alpha & Omega
(517) 349-8660
3654 Okemos Rd
Lansing, MI
 
Stillson Masonry
(616) 454-7540
1227 Houseman Ave Ne
Grand Rapids, MI
 
Hanneman & Fineis Concrete Construction Inc
(517) 371-4053
16101 S US Highway 27 Ste 6
Lansing, MI
 
Bornor Restoration Inc
(517) 482-1625
525 Filley St
Lansing, MI
 
Quadratic Masonry Llc
(734) 663-9646
3877 Albert Dr
Ann Arbor, MI
 
Stone Doctor
(248) 698-3161
White Lake Twp
Sterling Heights, MI
 
D 'S Chimney Repair Slupka Cha Ntell
(810) 742-2141
3829 Beechwood Ave
Flint, MI
 
Paul Henes Masonry
(734) 769-0880
3687 Jackson Rd
Ann Arbor, MI
 
Expert Construction Co
(586) 293-0920
31056 Shawn Dr
Warren, MI
 
Sivosky Steve
(810) 732-4490
6131 Mapleridge Dr
Flint, MI
 

Anchoring Columns to CMU Wythes

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: February 1, 2007

By Walter A. Laska

When masonry walls are constructed independent of the steel structure, anchorage of the masonry to the steel column is not required if the walls span vertically and are supported laterally by floors and roofs acting as diaphragms or structural members. However, if walls span horizontally, the concrete masonry must be anchored to the column to brace the wall laterally.

Distribution of the wind load acting on the wall is resisted by both wythes in proportion to their relative thickness. Joint reinforcement ties the brick wythe to the concrete masonry, which creates a positive bond. Wind loads are transferred from the brick wythe to the concrete masonry wythe and through the anchors to the steel column. This connection laterally braces the masonry wall to the steel column.

Use an adjustable anchor connection if a non-rigid connection between the masonry and the column is required. One type of adjustable anchor engages deformed rods welded to the column flanges at locations where the masonry wall completely bypasses the steel column and the column web is parallel to the wall. Deformed anchors can be supplied in continuous sections if spacing requirements are tight. This type of connection permits in-plane movement of the wall and laterally braces the masonry to the steel column.

Consider pull out strengths and resistance to buckling under load when selecting anchor types. Providi...